Test Code FBNC1 Brazil Nut Component rBer e 1


Specimen Required


Specimen Type: Serum

Container/Tube: Red or SST

Specimen Volume: 0.5 mL

Collection Instructions: Draw blood in a plain red-top tube(s), serum gel tube is acceptable. Spin down and send 0.5 mL of serum refrigerated in a plastic vial.


Secondary ID

75583

Method Name

ImmunoCAP FEIA

Reporting Name

Brazil Nut Component rBer e 1

Specimen Type

Serum

Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 28 days
  Frozen  365 days
  Ambient  28 days

Reject Due To

Gross hemolysis: Reject
Thawing: Warm OK; Cold OK
Gross lipemia: Reject

Reference Values

<0.10 kU/L

Interpretation

Class

IgE (kU/L)

Comment

0

<0.10

Negative

0/1

0.10 - 0.34

Equivocal/Borderline

1

0.35 - 0.69

Low Positive

2

0.70 - 3.49

Moderate Positive

3

3.50 - 17.49

High Positive

4

17.50 - 49.99

Very High Positive

5

50.00 - 99.99

Very High Positive

6

>99.99

Very High Positive

Performing Laboratory

Eurofins Viracor

CPT Code Information

86008

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FBNC1 Brazil Nut Component rBer e 1 64963-2

 

Result ID Test Result Name Result LOINC Value
Z5672 Brazil Nut Component rBer e 1 64963-2
Z5673 Class 103065-9

Day(s) Performed

Monday through Friday

Report Available