Sign in →

Test Code FSTAB Stachybotrys chartarum/atra IgE


Specimen Required


Collection Container/Tube: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL of serum

Collection Instructions: Draw blood in a plain red-top tube(s), serum gel tube(s) is acceptable. Spin down and send 0.5 mL of serum refrigerated in a plastic vial.


Method Name

ImmunoCAP FEIA

Reporting Name

Stachybotrys chartarum/atra IgE

Specimen Type

Serum

Specimen Minimum Volume

0.5 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 28 days
  Frozen  365 days
  Ambient  28 days

Reject Due To

Gross lipemia Reject

Reference Values

<0.35 kU/L

Interpretation

Class

IgE (kU/L)

Comment

0

<0.10

Negative

0/1

0.10-0.34

Equivocal/Borderline

1

0.35-0.69

Low Positive

2

0.70-3.49

Moderate Positive

3

3.50-17.49

High Positive

4

17.50-49.99

Very High Positive

5

50.00-99.99

Very High Positive

6

>99.99

Very High Positive

Day(s) Performed

Monday through Friday

Report Available

3 to 6 days

Performing Laboratory

Eurofins Viracor

Test Classification

This test was developed, and its performance characteristics determined by Eurofins Viracor. It has not been cleared or approved by the U.S. Food and Drug Administration.

CPT Code Information

86003

LOINC Code Information

Test ID Test Order Name Order LOINC Value
FSTAB Stachybotrys chartarum/atra IgE 29616-0

 

Result ID Test Result Name Result LOINC Value
Z4145 Stachybotrys chartarum/atra IgE 29616-0
Z5805 CLASS Not Provided