Test Code MHPRP Metamycoplasma hominis, Molecular Detection, PCR, Plasma
Reporting Name
Mycoplasma hominis PCR, PUseful For
Rapid, sensitive, and specific identification of Metamycoplasma hominis from plasma
This test is not intended for medicolegal use.
Method Name
Real-Time Polymerase Chain Reaction (PCR) using LightCycler and Fluorescent Resonance Energy Transfer (FRET)
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
Plasma EDTAOrdering Guidance
Shipping Instructions
Ship specimen refrigerated.
Specimen Required
The high sensitivity of amplification by polymerase chain reaction requires the specimen to be processed in an environment in which contamination of the specimen by Metamycoplasma hominis DNA is unlikely.
Collection Container/Tube:
Preferred: Lavender top (EDTA)
Acceptable: Royal blue top (EDTA), pink top (EDTA)
Submission Container/Tube: Screw-capped, sterile container
Specimen Volume: 1 mL
Collection Instructions: Centrifuge and aliquot plasma into a sterile vial within 24 hours of collection.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma EDTA | Refrigerated (preferred) | 7 days | |
Frozen | 7 days |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitabilityReference Values
Not applicable
Day(s) Performed
Monday through Friday
CPT Code Information
87798
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
MHPRP | Mycoplasma hominis PCR, P | 68546-1 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
MPSRC | Specimen Source | 31208-2 |
44134 | Mycoplasma hominis PCR, P | 68546-1 |
Secondary ID
65134Clinical Information
Metamycoplasma hominis, previously Mycoplasma hominis, has been associated with a number of clinically significant infections, although it is also part of the normal urogenital microbiota.
M hominis may be found in the respiratory specimens and spinal fluid of neonates. Although the clinical significance of such findings is often unclear, as spontaneous clinical recovery may occur without specific treatment. In premature infants, clinical manifestations of meningoencephalitis have been reported.
M hominis may play a role in some cases of pelvic inflammatory disease, usually in combination with other organisms. M hominis may be isolated from amniotic fluid of women with preterm labor, premature rupture of membranes, spontaneous term labor, or chorioamnionitis; there is evidence that it may be involved in postpartum fever or fever following abortion, usually as a complication of endometritis.
M hominis has rarely been associated with septic arthritis (including prosthetic joint infection), pyelonephritis, intraabdominal infection, wound infection, endocarditis, central nervous system infection (including meningoencephalitis, brain abscess, central nervous system shunt infection and subdural empyema), pneumonia, and infected pleural and pericardial effusions. Extragenital infection typically occurs in those with hypogammaglobulinemia or depressed cell-mediated immunity. In lung transplant recipients in particular, M hominis has been associated with pleuritis and mediastinitis. Recent evidence implicates donor transmission in some cases of M hominis infection in lung transplant recipients.
Polymerase chain reaction (PCR) detection of M hominis is sensitive, specific, and provides same-day results. Although this organism can occasionally be detected in routine plate cultures, this is neither a rapid nor a sensitive approach to detection. Specialized cultures are more time consuming than the described PCR assay. The described PCR assay has replaced conventional culture for M hominis at Mayo Clinic Laboratories due to its speed and equivalent performance to culture.
Interpretation
A positive polymerase chain reaction (PCR) result for the presence of a specific sequence found within the Metamycoplasma hominis tuf gene indicates the presence of M hominis DNA in the specimen.
A negative PCR result indicates the absence of detectable M hominis DNA in the specimen, but it does not rule-out infection as false-negative results may occur due to inhibition of PCR, sequence variability underlying the primers and probes, or the presence of M hominis in quantities less than the limit of detection of the assay.
Cautions
Interfering substances may affect the accuracy of this assay; results should always be interpreted in conjunction with clinical and epidemiological findings
Since Metaycoplasma hominis may be part of the normal microbiota, results should be interpreted accordingly.
This test does not detect other species of Metamycoplasma or Ureaplasma (including Mycoplasma pneumoniae, a common cause of community acquired pneumonia)
Supportive Data
Validation included spiking studies for Metamycoplasma hominis. Spiking studies were carried out using 30 EDTA whole blood and plasma samples spiked with genomic DNA for M hominis (as well as 10 unspiked specimens). Sensitivity and specificity were 100%.
Clinical Reference
1. Sampath R, Patel R, Cunningham SA, et al: Cardiothoracic transplant recipient Mycoplasma hominis: An uncommon infection with probable donor transmission, EBioMedicine 2017 May;19:84-90
2. Waites KB, Taylor-Robinson D: Mycoplasma and Ureaplasma. In: Jorgensen JH, ed. Manual of Clinical Microbiology. 11th ed. ASM Press; 2015:1088-1105
Method Description
This polymerase chain reaction (PCR) method employs a target-specific detection system, including primers and fluorescent resonance energy transfer (FRET) hybridization probes designed for the tuf gene of Metamycoplasma hominis. The LightCycler instrument amplifies and monitors target nucleic acid sequences by fluorescence during PCR cycling. This is an automated PCR system that can rapidly detect amplified product development. The detection of amplified products is based on the FRET principle. For FRET product detection, a hybridization probe with a donor fluorophore, fluorescein, on the 3' end is excited by an external light source, which emits light that is absorbed by a second hybridization probe with an acceptor fluorophore, LC-Red 640, on the 5' end. The acceptor fluorophore then emits light of a different wavelength that is measured with a signal that is proportional to the amount of specific PCR product. The process is completed in a closed-tube system.(Cunningham SA, Mandrekar JN, Rosenblatt JE, Patel R: Rapid PCR detection of Mycoplasma hominis, Ureaplasma urealyticum, and Ureaplasma parvum. Int J Bacteriol. 2013;2013:168742. doi: 10.1155/2013/168742)