Test Code MYOGL Myoglobin Immunostain, Technical Component Only

Reporting Name

Myoglobin IHC, Tech Only

Useful For

Marker of skeletal and cardiac muscle

Reflex Tests

Test ID Reporting Name Available Separately Always Performed
IHTOI IHC Initial, Tech Only No No
IHTOA IHC Additional, Tech Only No No

Method Name

Immunohistochemistry (IHC)

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Specimen Type

TECHONLY


Ordering Guidance


This test includes only technical performance of the stain (no pathologist interpretation is performed). If diagnostic consultation by a pathologist is required order PATHC / Pathology Consultation.



Shipping Instructions


Attach the green pathology address label and the pink Immunostain Technical Only label included in the kit to the outside of the transport container.



Specimen Required


Specimen Type: Tissue

Supplies: Immunostain Technical Only Envelope (T693)

Container/Tube: Immunostain Technical Only Envelope

Preferred:

-Formalin-fixed, paraffin-embedded tissue block

OR

-2 Unstained, positively charged glass slides (25- x 75- x 1-mm) per test ordered; sections 4-microns thick

Acceptable: None


Specimen Minimum Volume

See Specimen Required

Specimen Stability Information

Specimen Type Temperature Time Special Container
TECHONLY Ambient (preferred)
  Refrigerated 

Reject Due To

Wet/frozen tissue 
Cytology smears 
Nonformalin fixed tissue 
Nonparaffin embedded tissue 
Noncharged slides 
ProbeOn slides 
Snowcoat slides 
Reject 

Day(s) Performed

Monday through Friday

CPT Code Information

88342-TC, primary

88341-TC, if additional IHC

LOINC Code Information

Test ID Test Order Name Order LOINC Value
MYOGL Myoglobin IHC, Tech Only Order only;no result

 

Result ID Test Result Name Result LOINC Value
70829 Myoglobin IHC, Tech Only Bill only; no result

Secondary ID

70517

Clinical Information

Myoglobin is found in skeletal and cardiac muscle, but not in smooth muscle, and functions as an oxygen transporting pigment. Antibodies to myoglobin may be useful in the diagnosis of rhabdomyosarcomas, but the proportion of positive cells may be small and may be distributed unevenly in the section. Staining for myoglobin is not seen in carcinomas or in other sarcomas.

Interpretation

This test does not include pathologist interpretation, only technical performance of the stain. If interpretation is required, order PATHC / Pathology Consultation for a full diagnostic evaluation or second opinion of the case.

 

The positive and negative controls are verified as showing appropriate immunoreactivity and documentation is retained at Mayo Clinic Rochester. If a control tissue is not included on the slide, a scanned image of the relevant quality control tissue is available upon request, call 855-516-8404.

 

Interpretation of this test should be performed in the context of the patient's clinical history and other diagnostic tests by a qualified pathologist.

Cautions

Age of a cut paraffin section can affect immunoreactivity. Stability thresholds vary widely among published literature and are antigen dependent. Best practice is for paraffin sections to be cut within 6 weeks.

 

The charge of glass slides can be affected by environmental factors and subsequently may alter slide staining. Sending unsuitable glass slides can result in inconsistent staining due to poor slide surface chemistry.

 

Best practices for storage of positively charged slides:

-Minimize time slides are stored after being unpackaged

-Limit exposure to high humidity and heat

-Minimize exposure to plastics

Clinical Reference

1. Brooks JJ. Immunohistochemistry of soft tissue tumors. Myoglobin as a tumor marker for rhabdomyosarcoma. Cancer. 1982;50:1757-1763

2. Furlong MA, Mentzel T, Fanburg-Smith JC. Pleomorphic rhabdomyosarcoma in adults: a clinicopathologic study of 38 cases with emphasis on morphologic variants and recent skeletal muscle-specific markers. Mod Pathol. 2001;14(6):595-603

3. Kagawa N, Sano T, Inaba H, Mori K, Hizawa K. Immunohistochemistry of myoglobin in rhabdomyosarcomas. Acta Pathol Jpn. 1983;33(3):515-522

4. Elsherbiny ME, Shaaban M, El-Tohamy R, et al. Expression of myoglobin in normal and cancer brain tissues: Correlation with hypoxia markers. Front Oncol. 2021;11:590771. doi:10.3389/fonc.2021.590771

5. Magaki S, Hojat SA, Wei B, So A, Yong WH. An introduction to the performance of immunohistochemistry. Methods Mol Biol. 2019;1897:289-298. doi:10.1007/978-1-4939-8935-5_25

Method Description

Immunohistochemistry on sections of paraffin-embedded tissue.(Unpublished Mayo method)

Report Available

1 to 3 days

Specimen Retention Time

Until staining is complete.

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

Forms

If not ordering electronically, complete, print, and send a Immunohistochemical (IHC)/In Situ Hybridization (ISH) Stains Request (T763) with the specimen.