Mayo Clinic Laboratories

Test Code SOFT: VANCP Vancomycin, Peak, Serum

Additional Codes

Ordering Mnemonic

EPIC NAME: VANCOMYCIN LEVEL, PEAK

EPIC CODE: LAB41

 

Performing Laboratory

Saint Francis Medical Center-Drug Monitoring

Specimen Requirements

Specimen Type: Serum, lithium heparin, EDTA plasma

Container/Tube: No gel tubes will be accepted

Specimen Volume: 0.5 mL

NICU Min. Volume: 250 Micro Liters

Collection Instructions: Serum for a peak level is usually drawn 1 to 2 hours after infusion.

 

Specimen Transport Temperature

48 hours at 15-25 C

14 days at 2-8 C

12 months at -20 C

Reference Values

30-40 µg/mL

Toxic value (automatic call-back):  >40 µg/mL

Day(s) Test Set Up

Monday through Sunday

Test Classification and CPT Coding

80202

Methodology

Enzyme Immunoassay (EIA)