Test Code SOFT: Z0199 Coagulation Factor IX Activity Assay, Plasma
Additional Codes
Ordering Mnemonic | Mayo Test ID |
---|---|
EPIC NAME: FACTOR 9 ACTIVITY | F_9 |
EPIC CODE: LAB308
Reporting Name
Coag Factor IX Assay, PUseful For
Diagnosing deficiencies, particularly hemophilia B (Christmas disease)
Assessing the impact of liver disease on hemostasis
Investigation of a prolonged activated partial thromboplastin time
Testing Algorithm
For information see Hemophilia Testing Algorithm
Method Name
Optical Clot-Based
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
Plasma Na CitOrdering Guidance
Coagulation testing is highly complex, often requiring the performance of multiple assays and correlation with clinical information. For that reason, consider ordering a Coagulation Consultation.
Necessary Information
If priority specimen, mark request form, give reason, and request a call-back.
Specimen Required
Specimen Type: Platelet-poor plasma
Patient Preparation: Patient must not be receiving Coumadin (warfarin) or heparin therapy.
Collection Container/Tube: Light-blue top (3.2% sodium citrate)
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions:
1. Specimen must be collected prior to factor replacement therapy.
2. For complete instructions, see Coagulation Guidelines for Specimen Handling and Processing.
3. Centrifuge, transfer all plasma into a plastic vial, and centrifuge plasma again.
4. Aliquot plasma into a plastic vial, leaving 0.25 mL in the bottom of centrifuged vial.
5. Freeze plasma immediately (no longer than 4 hours after collection) at -20° C or ideally, at or below -40° C.
Additional Information:
1. Double-centrifuged specimen is critical for accurate results as platelet contamination may cause spurious results.
2. Each coagulation assay requested should have its own vial.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Plasma Na Cit | Frozen | 14 days |
Reject Due To
Gross hemolysis | Reject |
Gross lipemia | Reject |
Gross icterus | Reject |
Special Instructions
Reference Values
≤6 months: Normal, full-term newborn infants or healthy premature infants may have decreased levels (≥20%), which may not reach adult levels for 180 or more days postnatal.* (Literature derived)
>6 months: 65-140%
*See Pediatric Hemostasis References section in Coagulation Guidelines for Specimen Handling and Processing.
Day(s) Performed
Monday through Saturday
CPT Code Information
85250
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
F_9 | Coag Factor IX Assay, P | 3187-2 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
F_9 | Coag Factor IX Assay, P | 3187-2 |
Test Classification
This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.Disease States
- Hemophilia B
Clinical Information
Factor IX is a vitamin K-dependent serine protease synthesized in the liver and participates in the intrinsic coagulation pathway. Its biological half-life is 18 to 24 hours.
Congenital deficiency is inherited as an X-linked recessive bleeding disorder (hemophilia B). Severe deficiency (<1%) is characterized by hemarthroses, deep tissue bleeding, excessive bleeding with trauma, and ecchymoses.
Acquired deficiency is associated with liver disease, vitamin K deficiency, warfarin therapy, and inhibitors (rare).
Interpretation
Acquired deficiency is more common than congenital.
Mild hemophilia B: 5% to 50% activity
Moderate hemophilia B: 1% to 5% activity
Severe hemophilia B: <1% activity
Cautions
Liver disease, warfarin therapy, or vitamin K deficiency may decrease factor IX levels.
Clinical Reference
1. Barrowcliffe TW, Raut S, Sands D, Hubbard AR. Coagulation and chromogenic assays of factor VIII activity: general aspects, standardization, and recommendations. Semin Thromb Hemost. 2002;28(3):247-256
2. Franchini M, Lippi G, Favaloro EJ. Acquired inhibitors of coagulation factors: part II. Semin Thromb Hemost. 2012;38(5):447-453
3. Carcao MD. The diagnosis and management of congenital hemophilia. Semin Thromb Hemost. 2012;38(7):727-734
4. Favaloro EJ, Lippi G, eds. Hemostasis and Thrombosis: Methods and Protocols. Humana Press; 2017
Method Description
The factor IX assay is performed on the Instrumentation Laboratory ACL TOP using the activated partial thromboplastin time (aPTT) method and a factor-deficient substrate. Patient plasma is combined and incubated with a factor IX-deficient substrate (normal plasma depleted of factor IX by immunoadsorption) and an aPTT reagent. After a specified incubation time, calcium is added to trigger the coagulation process in the mixture. Then the time to clot formation is measured optically at a wavelength of 671 nm.(Owen CA Jr, Bowie EJW, Thompson JH Jr. Diagnosis of Bleeding Disorders. 2nd ed. Little, Brown and Company; 1975; Cielsa B. Defects of plasma clotting factors. In: Hematology in Practice. 3rd ed. FA Davis; 2019:chap 17)
Report Available
1 to 3 daysSpecimen Retention Time
7 daysForms
If not ordering electronically, complete, print, and send a Coagulation Test Request (T753) with the specimen.