Test Code SOFT: Z1000 Carnitine, Serum
Additional Codes
Ordering Mnemonic | Mayo Test ID |
---|---|
EPIC NAME: MISC. LAB TEST | CARNS |
EPIC CODE: LAB000
Reporting Name
Carnitine, SUseful For
Evaluation of patients with a clinical suspicion of a wide range of conditions including organic acidemias, fatty acid oxidation disorders, and primary carnitine deficiency using serum specimens
Method Name
Flow Injection Analysis-Tandem Mass Spectrometry (FIA-MS/MS)
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
SerumNecessary Information
Patient's age is required.
Specimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 0.5 mL
Collection Instructions: Centrifuge and aliquot serum into a plastic vial.
Specimen Minimum Volume
0.2 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Frozen (preferred) | 60 days | |
Refrigerated | 21 days | ||
Ambient | 7 days |
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Reference Values
|
Total carnitine (TC) |
Free carnitine (FC) |
Acylcarnitine (AC) |
AC/FC Ratio |
Age Group |
Range* |
Range* |
Range* |
Range |
≤1 day |
23-68 |
12-36 |
7-37 |
0.4-1.7 |
2-7 days |
17-41 |
10-21 |
3-24 |
0.2-1.4 |
8-31 days |
19-59 |
12-46 |
4-15 |
0.1-0.7 |
32 days-12 months |
38-68 |
27-49 |
7-19 |
0.2-0.5 |
13 months-6 years |
35-84 |
24-63 |
4-28 |
0.1-0.8 |
7-10 years |
28-83 |
22-66 |
3-32 |
0.1-0.9 |
11-17 years |
34-77 |
22-65 |
4-29 |
0.1-0.9 |
≥18 years |
34-78 |
25-54 |
5-30 |
0.1-0.8 |
Schmidt-Sommerfeld E, Werner E, Penn D: Carnitine plasma concentrations in 353 metabolically healthy children. Eur J Pediatr. 1988;147:356-360
Used with permission of European Journal of Pediatrics.
Day(s) Performed
Monday through Friday
CPT Code Information
82379
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
CARNS | Carnitine, S | 97182-0 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
32045 | Total | 14288-5 |
32046 | Free (FC) | 14286-9 |
32047 | Acylcarnitine (AC) | 14282-8 |
32048 | AC/FC Ratio | 30193-7 |
32049 | Interpretation | 59462-2 |
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.Clinical Information
Carnitine and its esters are required for normal energy metabolism and serve 4 primary functions:
-Importing long-chain fatty acids into the mitochondria
-Exporting naturally-occurring short-chain acyl-CoA groups from the mitochondria
-Maintaining the ratio of free CoA to esterified CoA
-Removing potentially toxic acyl-CoA groups from the cells and tissues
Evaluation of carnitine in serum, plasma, and urine is a biochemical screening test for suspected primary disorders of the carnitine cycle or secondary disturbances in carnitine levels as a result of organic acidemias and fatty acid oxidation disorders. In the latter disorders, acyl-CoA groups accumulate and are excreted into the urine and bile as carnitine derivatives, resulting in a secondary carnitine deficiency. More than 100 such primary and secondary disorders have been described. Collectively, their incidence is approximately 1 in 1000 live births. Primary carnitine deficiency has an incidence of approximately 1 in 21,000 live births based on Minnesota newborn screening data.
Other conditions that could cause an abnormal carnitine level include neuromuscular diseases, gastrointestinal disorders, familial cardiomyopathy, renal tubulopathies and chronic renal failure (dialysis), and prolonged treatment with steroids, antibiotics (pivalic acid), anticonvulsants (valproic acid), and total parenteral nutrition.
Follow-up testing is required to differentiate primary and secondary carnitine deficiencies and to elucidate the exact cause.
Interpretation
When abnormal results are detected, a detailed interpretation is given, including an overview of the results and of their significance, a correlation to available clinical information, elements of differential diagnosis, recommendations for additional biochemical testing, and a phone number to reach one of the laboratory directors in case the referring physician has additional questions.
Cautions
Increased values may be obtained after carnitine supplementation or meat consumption.
Clinical Reference
1. Magoulas PL, El-Hattab AW. Systemic primary carnitine deficiency: an overview of clinical manifestations, diagnosis, and management. Orphanet J Rare Dis. 2012;18;7:68
2. Longo N, Amat di San Filippo C, Pasquali M. Disorders of carnitine transport and the carnitine cycle. Am J Med Genet C Semin Med Genet. 2006;142C(2):77-85
3. Zammit VA, Ramsay RR, Bonomini M, Arduini A. Carnitine, mitochondrial function and therapy. Adv Drug Deliv Rev. 2009;61(14):1353-1362
4. El-Hattab AW: Systemic primary carnitine deficiency. In: Adam MP, Ardinger HH, Pagon RA, et al, eds. GeneReviews [Internet]. University of Washington, Seattle; 2012. Updated November 3, 2016. Accessed November 27, 2023. Available at www.ncbi.nlm.nih.gov/books/NBK84551/
5. Longo N., Frigeni M., Pasquali M. Carnitine transport and fatty acid oxidation. Biochim. Biophys. Acta. 2016;1863:2422-2435
6. Almannai M, Alfadhel M, El-Hattab AW. Carnitine inborn errors of metabolism. Molecules. 2019;24(18):3251
Method Description
Free and total carnitines are measured by tandem mass spectrometry (MS/MS) stable isotope dilution analysis. Hydrolysis enables measurement of total carnitine, and esterified carnitine (acylcarnitine) is calculated as the difference between the total and free carnitine. Quantification is enabled using deuterium-labeled carnitine (d3-carnitine) added as internal standard. A selected reaction monitoring experiment is performed by MS/MS. The first mass spectrometer detects carnitine and d3-carnitine precursors and transmits them to a collision cell within the mass spectrometer where they are fragmented. Specific fragments derived from the carnitine and internal standard are monitored in the second mass spectrometer.(Stevens RD, Hillman SL, Worthy S, Sanders D, Millington DS. Assay for free and total carnitine in human plasma using tandem mass spectrometry. Clin Chem. 2000;46(5):727-729; Miller MJ, Cusmano-Ozog K, Oglesbee D, Young S. ACMG Laboratory Quality Assurance Committee. Laboratory analysis of acylcarnitines, 2020 update: a technical standard of the American College of Medical Genetics and Genomics [ACMG]. Genet Med. 2021;23[2]:249-258)
Report Available
3 to 5 daysSpecimen Retention Time
1 monthHighlights
Carnitine levels are disturbed in primary disorders of the carnitine cycle, or secondary disturbances of carnitine metabolism due to other biochemical disorders.
Additional testing is required to distinguish between primary and secondary deficiencies of carnitine.
Dietary intake (meat, carnitine supplementation) may cause increased carnitine values.
Abnormal results are accompanied by detailed interpretation including recommendations for follow-up testing.
Forms
If not ordering electronically, complete, print, and send a Biochemical Genetics Test Request (T798) with the specimen.