Test Code SOFT: Z1000 Iohexol, Timed Collection, Urine
Additional Codes
Ordering Mnemonic | Mayo Test ID |
EPIC NAME: MISC. LAB TEST | HEXU |
EPIC CODE: LAB000 |
Reporting Name
Iohexol, UUseful For
Determining glomerular filtration rate in urine specimens
Method Name
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
UrineSpecimen Required
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Container/Tube: Plastic vial
Specimen Volume: 5 mL
Collection Instructions: Collect a timed urine specimen. Timing may be variable and patient dependent.
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Urine | Refrigerated (preferred) | 7 days | |
Frozen | 35 days | ||
Ambient | 7 days |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability.Reference Values
Not applicable
Day(s) Performed
Monday through Friday
CPT Code Information
82542
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
HEXU | Iohexol, U | 93973-6 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
61712 | Iohexol, U | 93973-6 |
Test Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.Clinical Information
The assessment of glomerular filtration rate (GFR) is an important parameter of kidney function utilized by clinicians in the care of patients with varying kidney diseases, and for clinical research when precise assessment of kidney function is necessary. The GFR is the sum of all the filtration rates of the individual nephrons within the kidney and, as such, reflects the number of functioning nephrons.
Urine concentrations of iohexol can be used for measurement of GFR following a subcutaneous injection of iohexol (plasma disappearance), or during a continuous infusion of iohexol when used in conjunction with plasma iohexol determinations (HEXP / Iohexol, Plasma). The results can be used to determine the clearance of iohexol, which is a measure of GFR.
Cautions
A theoretical complication to injection of iodinated contrast media (one that has not been observed clinically to date) is the transient suppression of thyroid function in premature and newborn infants. Therefore, a sensitive thyrotropin test is suggested approximately 2 to 3 weeks after an iohexol clearance in that age group.
Clinical Reference
1. Brown SC, O'Reilly PH. Iohexol clearance for the determination of glomerular filtration rate in clinical practice: evidence for a new gold standard. J Urol. 1991;146(3):675-679
2. Gaspari F, Perico N, Ruggenenti P, et al. Plasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate. J Am Soc Nephrol. 1995;6(2):257-263
3. Schwartz GJ, Abraham AG, Furth SL, Warady BA, Munoz A. Optimizing iohexol plasma disappearance curves to measure the glomerular filtration rate in children with chronic kidney disease. Kidney Int. 2010;77(1):65-71
4. Schmit DJ, Carroll LJ, Eckfeldt JH, Seegmiller JC. Verification of separate measurement procedures where analytical determinations influence the clinical interpretation of GFR: Iohexol quantitation by HPLC and LC-MS/MS. Clin Biochem. 2019;67:16-23
5. Seegmiller JC, Burns BE, Schinstock CA, Lieske JC, Larson TS. Discordance between iothalamate and iohexol urinary clearances. Am J Kid Dis. 2016;67(1):49-55
Method Description
Timed urine specimens are obtained after subcutaneous injection of nonradiolabeled iohexol. Iohexol results are acquired via a liquid chromatography tandem mass spectrometry (LC-MS/MS) system. A ThermoFisher LX-2 Cohesive high-performance liquid chromatography system and an ABSciex 5500 MS/MS are used for analysis.(Seegmiller JC, Burns BE, Lieske JC, et al. Discordant glomerular filtration rate determinations between iothalamate and iohexol renal clearances. Poster presented at: Renal Week 2010. 43rd Annual Meeting of the American Society of Nephrology; November 16-21, 2010; Denver, CO)
Report Available
3 to 4 daysSpecimen Retention Time
7 daysSecondary ID
606985Forms
If not ordering electronically, complete, print, and send a Renal Diagnostics Test Request (T830) with the specimen.